FIRE INTEGRATION MODULE

Ref: 14496000

Unlimited fire elements

Fire Integration module provides a complete integration of the Fire panel into DASSnet Security Management System (SMS)
Which Fire panel systems can be integrated into DASSnet?

-Most of the most used Fire panel systems are already integrated in DASSnet. Check the list to know if your Fire panel system is available.

What if my Fire panel system is not in the list?

-DORLET will develop the integration upon request.

FIRE PANEL INTEGRATED

BRAND MODEL/PROTOCOL
AGUILERA AEJ94-C2 (V2.5, v3.2)
AGUILERA Algorithmic system (V1.7)
ALGORINET BC 216 (SAM/0227/AN)
BOSCH UEZ-2000 (V.2.01) FPA5000
BOSCH  FPA5000 (OPC through TCP)
CERBERUS MK7022 (CS10 I CS/11) 
ESSER IQ8
KILSEN KSA-700 (V.1.0)
NOTIFIER  AM-2020 FACP
NOTIFIER 3000-MN-DT-195
NOTIFIER  ID1000
ZETTLER ZETFAS 210 255 BA
ZITON ZCP2 (2.01)
ALARMS INTEGRATION CONFIGURATION

The integration of a Ffire panel into the DASSnet is as easy as, selecting from the list the system and configure the connexion by IP address, user and password or serial connection.

Once there is connection with the fire panel, you will be able to add all fire elements contained in the fire panel.

Go back

ALARMS MONITOR

Get complete online view of the alarms status in the alarm monitor, the devices tree and the map view. 

Every alarm can be acknowledged or rearmed from the alarm monitor, the devices tree and the map view.

Each alarm is defined by the alarm name, device name, device type, date and time of the activation, date and time of the acknowledge, and the priority. 

The alarms are shorted using priorities. The total amount of active alarms can be visualized in the priority scaled chart.

Every alarm can be automatically displayed in the map view, at the time is activated, or manually by clicking on the link in the alarm monitor.

Go back

ALARMS AUTOMATIC ACTIONS

Create automatic event-action actuations between all integrated devices in the SMS and the ALARM panels. 

EVENTS: Activated input, Deactivate input, Superior pre-alarm, Inferior pre-alarm, Invalid access by reader, Access valid by reader, Controlled armed by reader, Controller disarmed by reader, Swipe of tour card on reader, Door left opened, Door forced, Disconnected controller, Power failure, Activated tamper, Empty control space, No empty control space, Parking full, Parking not ful, Active fire sensor, Active fire button, Set in out of surveillance, Set in failure, No video signal.

ACTIONS: Activate output, Deactivate output, Open door, Close door, Opening pulse, Arm controller, Disarm controller, Arm group, Disarm group, Forced arming, Disarm group and Forced arming, Evacuate, Finish evacuation, Inhibit reader, Set in surveillance, Set in out of surveillance, Show camera, Assign camera to screen, Place camera in preset, Start recording, Start playing message, Open controlled space all readers, Open controlled space entry readers, Open controlled space exit readers, Close controlled space all readers, Close controlled space entry readers, Close controlled space exit readers, Send mail notification

This feature needs the Alarms module.

Go back